Clinical Studies

Guidelines for Preventing Surgical Site Infection (SSI)

American Society of Colon and Rectal Surgeons (ASCRS)

Excerpt: Clinical practice guidelines for preventing surgical site infection:
“Wound protectors can decrease the incidence of SSI after colorectal surgery. Strength of recommendation: strong based on high-quality evidence. …

“… Double-ring devices were found to exhibit a greater protective effect than single-ring devices.”

Reference: Shogan BD, Vogel JD, Davis BR, et al. The American Society of Colon and Rectal Surgeons Clinical Practice Guidelines for Preventing Surgical Site Infection. Dis Colon Rectum. 2024;67(11):1368-1382. doi:10.1097/DCR.0000000000003450

Read the full article

Society of Healthcare Epidemiology of America (SHEA)/Infectious Diseases Society of America (IDSA)/Association for Professionals in Infection Control & Epidemiology (APIC)/American Health Association (AHA)/Joint Commission

Excerpt: Essential practices for preventing SSI recommended for all acute-care hospitals:
“Use impervious plastic wound protectors for gastrointestinal and biliary tract surgery. (Quality of Evidence: HIGH)”

Reference: Calderwood MS, Anderson DJ, Bratzler DW, et al. Strategies to prevent surgical site infections in acute-care hospitals: 2022 update. Infect Control Hosp Epidemiol. 2022;43(6):681-713. doi:10.1017/ice.2022.87

Read the full article

American College of Surgeons/Surgical Infection Society (ACS/SIS)

Excerpt: Guidelines for the prevention, detection and management of SSIs:
“The use of an impervious plastic wound protector can prevent SSI in open abdominal surgery, and evidence is strongest for elective colorectal and biliary tract procedures.”

Reference: Ban KA, Minei JP, Laronga C, et al. Executive summary of the American College of Surgeons/Surgical Infection Society surgical site infection guidelines—2016 update. J Am Coll Surg. 2017;224(1):59-74. doi:10.1016/j.jamcollsurg.2016.10.001

Read the full article

World Health Organization (WHO)

Excerpt: The conditional guideline recommendations for wound protector:
“Consider the use of wound protector devices in clean-contaminated, contaminated and dirty abdominal surgical procedures for the purpose of reducing the rate of SSI.”

Reference: World Health Organization. Global guidelines for the prevention of surgical site infection. 2nd ed. Geneva, Switzerland: World Health Organization; 2018. ISBN: 9789241550475

Read the full article

World Society of Emergency Surgery (WSES)

Excerpt: Guidelines for reducing the incidence of SSI in emergency abdominal surgery:
“The use of wound protectors has protective effects in reducing incisional SSI (GoR 1A). …

“… The use of dual-ring constructed wound protectors appears to be superior to single-ring devices in preventing SSI (GoR 1B).”

Reference: De Simone B, Sartelli M, Coccolini F, et al. Intraoperative surgical site infection control and prevention: a position paper and future addendum to WSES intra-abdominal infections guidelines. World J Emerg Surg. 2020;15:10. doi:10.1186/s13017-020-00294-4

Read the full article

Enhanced Recovery After Surgery (ERAS) Society

Excerpt: Consensus guidelines for perioperative care for emergency laparotomies:
“Routine use of a fascia abdominal wound protector, abdominal irrigation and new gloves and closure instruments are recommended to reduce SSI. (Evidence level: Moderate, Recommendation grade: Strong)”

Reference: Scott MJ, Aggarwal G, Aitken RJ, et al. Consensus guidelines for perioperative care for emergency laparotomy: Enhanced Recovery After Surgery (ERAS®) Society recommendations. Part 2—Emergency laparotomy: intra- and postoperative care. World J Surg. 2022;46(6):1354-1366. doi:10.1007/s00268-022-06552-y

Read the full article

Colon and Rectal

Efficacy of Wound Protectors in Reducing Surgical Site Infections in Patients Undergoing Open Colorectal Surgery: A Systematic Review and Meta-analysis

Excerpt: “We included 6 RCTs comprising 666 patients, of whom 327 (49 %) were randomised to the wound protectors’ group. ... The incidence of SSIs was significantly lower in the intervention group (RR 0.44; 95% CI 0.22–0.88; p=0.021). Subgroup analysis of four RCTs evaluating Alexis-O ring wound retractors showed a significantly lower incidence of SSIs in the experimental group (RR 0.21; 95% CI 0.09–0.48; p< 0.001).”

Reference: Desai A, Bisht R, Misra S, Kritya M, Bhardwaj A, Chakraborty S, et al. Efficacy of wound protectors in reducing surgical site infections in patients undergoing open colorectal surgery: A systematic review and meta-analysis. Colorectal Dis. 2026;28:e70401. doi:10.1111/codi.70401

Read the full article

Wound Protectors in Reducing Surgical Site Infections in Lower Gastrointestinal Surgery: An Updated Meta-analysis

Excerpt: “We demonstrated evidence of a subgroup difference where dual-ring wound protectors reduced SSIs while single-ring retractors did not, which provides greater insight in the choice of wound protection devices. …

“… Our meta-analysis found that dual-ring wound protectors reduce the odds of SSI (surgical site infection) in patients undergoing lower gastrointestinal surgery.”

Reference: Zhang L, Elsolh B, Patel SV. Wound protectors in reducing surgical site infections in lower gastrointestinal surgery: an updated meta-analysis. Surg Endosc. 2018;32(3):1111-1122. doi:10.1007/s00464-017-6012-0

Read the full article

Wound Protectors Reduce Surgical Site Infection: A Meta-analysis of Randomized Controlled Trials

Excerpt: “Our study suggests that the use of wound protectors decreases the risk of SSI by 45%. Our number needed to treat suggests that only 10 patients would have to be treated intraoperatively with a wound protector to prevent 1 SSI. ...

“Impervious plastic wound protectors reduce the risk of SSI (surgical site infection) when employed in non-trauma-related gastrointestinal and biliary tract surgery. Wound protectors represent a safe and simple intervention that may reduce postoperative morbidity and mortality.”

Reference: Edwards JP, Ho AL, Tee MC, Dixon E, Ball CG. Wound protectors reduce surgical site infection: a meta-analysis of randomized controlled trials. Ann Surg. 2012;256(1):53-59. doi:10.1097/SLA.0b013e3182570372

Read the full article

Plastic Wound Retractors as Bacteriological Barriers in Gastrointestinal Surgery: A Prospective Multi-institutional Trial

Excerpt: “In summary, use of a plastic wound retractor may result in reduced enteric bacterial colonization of the surgical incision site during gastrointestinal surgery. Reduced colonization of the surgical incision site by enteric bacteria due to the use of a plastic wound retractor should result in a reduction in SSI (surgical site infection) following gastrointestinal surgery.”

Reference: Mohan HM, McDermott S, Fenelon L, et al. Plastic wound retractors as bacteriological barriers in gastrointestinal surgery: a prospective multi-institutional trial. J Hosp Infect. 2012;81(2):109-113. doi:10.1016/j.jhin.2012.03.005

Read the full article

Alexis O-Ring Wound Retractor vs Conventional Wound Protection for the Prevention of Surgical Site Infections in Colorectal Resections

Excerpt: “The [Alexis] wound retractor is more effective in preventing SSI (surgical site infection) in elective colorectal resections compared with conventional methods.”

Reference: Cheng KP, Roslani AC, Sehha N, et al. ALEXIS O-Ring wound retractor vs conventional wound protection for the prevention of surgical site infections in colorectal resections. Colorectal Dis. 2012;14(6):e346-e351. doi:10.1111/j.1463-1318.2012.02943.x

Read the full article

A Wound Protector Shields Incision Sites from Bacterial Invasion

Excerpt: “These results suggest that the [wound protector] protects an incision site from bacterial invasion. …

“... We consider that the low incidence of SSI (surgical site infection) may have resulted from the protective effects of the [wound protector].”

Reference: Horiuchi T, Tanishima H, Tamagawa K, et al. A wound protector shields incision sites from bacterial invasion. Surg Infect (Larchmt). 2010;11(6):501-503. doi:10.1089/sur.2009.072

Read the full article

Barrier Wound Protection Decreases Surgical Site Infection in Open Elective Colorectal Surgery: A Randomized Clinical Trial

Excerpt: “In this study the use of barrier wound protection in elective open colorectal resectional surgery resulted in a clinically significant reduction in incisional surgical site infections. Barrier wound protection of this nature should be considered routine in this type of surgery.”

Reference: Reid K, Pockney P, Draganic B, Smith SR. Barrier wound protection decreases surgical site infection in open elective colorectal surgery: a randomized clinical trial. Dis Colon Rectum. 2010;53(10):1374-1380. doi:10.1007/DCR.0b013e3181ed3f7e

Read the full article

Randomized, Controlled Investigation of the Anti-infective Properties of the Alexis Retractor/Protector of Incision Sites

Excerpt: “The results of this study demonstrate that wound infection decreased significantly in the with Alexis retractor group.”

Reference: Horiuchi T, Tanishima H, Tamagawa K, et al. Randomized, controlled investigation of the anti-infective properties of the Alexis retractor/protector of incision sites. J Trauma. 2007;62(1):212-215. doi:10.1097/01.ta.0000196704.78785.ae

Read the full article

Bariatric

Alexis Wound Retractor in Roux-En-Y Gastric Bypass: Reducing Surgical Site Infection Associated with Circular Stapler Use

Excerpt: “Use of the Alexis wound retractor significantly reduced the rate of superficial SSI for patients undergoing RYGB with circular stapler-constructed gastrojejunostomy. Utilization … can decrease morbidity and cost associated with SSI.”

Reference: Pechman D, Munoz Flores F, Needham V, Salas Parra R, Cupello G, Palacios Diaz F, Camacho D. Alexis wound retractor in Roux-en-Y gastric bypass: reducing surgical site infection associated with circular stapler use. Surg Obes Relat Dis. 2020;16(8):1085-1090. doi:10.1016/j.soard.2020.04.030

Read the full article

Dual Ring Wound Protector Reduces Circular Stapler Related Surgical Site Infections in Patients Undergoing Laparoscopic Roux-En-Y Gastric Bypass

Excerpt: “In our retrospective study, of 158 consecutive patients undergoing LRYGB with circular stapled gastrojejunostomy, the use of a dual ring wound protector significantly decreased SSIs from 9.5% in our pre-intervention group to 1.35% in our post-intervention group.”

Reference: Chen J, Miller M, Ibele A, Morrow E, Glasgow R, Volckmann E. Dual ring wound protector reduces circular stapler–related surgical site infections in patients undergoing laparoscopic Roux-en-Y gastric bypass. Obes Surg. 2018;28(10):3352-3359. doi:10.1007/s11695-018-3394-6

Read the full article

General

Efficacy of a Dual-Ring Wound Protector for Prevention of Surgical Site Infections After Pancreaticoduodenectomy in Patients with Intrabiliary Stents: A Randomized Clinical Trial

Excerpt: “Among adult patients with intrabiliary stents, the use of a dual-ring wound protector during [pancreaticoduodenectomy] significantly reduces the risk of incisional SSI (surgical site infection). …

“In summary, use of a dual-ring wound protector for patients who received an intrabiliary stent before undergoing a [pancreaticoduodenectomy] had a 52% relative risk reduction in subsequent incisional SSIs.”

Reference: Bressan AK, Aubin JM, Martel G, et al. Efficacy of a Dual-ring Wound Protector for Prevention of Surgical Site Infections After Pancreaticoduodenectomy in Patients With Intrabiliary Stents: A Randomized Clinical Trial. Ann Surg. 2018;268(1):35-40. doi:10.1097/SLA.0000000000002614

Read the full article

Use of Wound-Protection System and Postoperative Wound-Infection Rates in Open Appendectomy

Excerpt: “Our data demonstrate that a statistically significant reduction in the incidence of wound infection was achieved with the use of a wound-protection device. …

“… This technique could be applied to a broader spectrum of open surgical procedures and ultimately reduce the economic and emotional burden of a preventable SSI (surgical site infection).”

Reference: Lee P, Waxman K, Taylor B, Yim S. Use of Wound-Protection System and Postoperative Wound-Infection Rates in Open Appendectomy: A Randomized Prospective Trial. Arch Surg. 2009;144(9):872–875. doi:10.1001/archsurg.2009.151

Read the full article

Scar Assessment after Thyroidectomy Using Alexis Wound Protector: A Prospective Cohort Study

Excerpt: “The Alexis® retractor ring allows the tissue to be exposed in thyroid and parathyroid surgery with a minimal incision in a quick, simple and static manner. The device improves visibility compared to other methods, while facilitating hemostasis and protecting the skin from traction injuries.”

Reference: Lois-Ortega Y, García-Curdi F, Brotons-Durbán S, Vendrell-Marqués JB. Use of Alexis retractor in thyroid and parathyroid surgery. Cir Esp. 2019;97(1):46-49. doi:10.1016/j.ciresp.2018.06.013

Read the full article

EGS P25 Innovative Use of Alexis O System for Tissue Retraction in Hernia and Abdominal Wall Wound Repairs

Excerpt: “The use of an Alexis O retractor in hernia repairs can improve the overall skin and subcutaneous tissue retraction aiding in abdominal wall closure and hernia repairs including umbilical, para-umbilical and inguinal hernias. It provides effective symmetrical retraction of skin and subcutaneous tissue, providing increased freedom to the surgeons and assistants and helps to avoid instrumental clashes.”

Reference: Johnston M, Sher J, Zino S, Tasnim T. EGS P25 Innovative use of Alexis® O System for tissue retraction in hernia and abdominal wall wound repairs. BJS. 2022;109(Suppl). doi:10.1093/bjs/znac404.090

Read the full article

Cardiothoracic

Advantages of Wound Retractor Device Versus Rigid Trocar at Camera Port in Video-Assisted Thoracic Surgery – A Single Institution Experience

Excerpt: “Patients who had [a wound retractor] showed less postoperative pain. Moreover, [wound retractors] presented other advantages: camera protection by small bleeding from chest wall, adaptability with every chest wall thickness, absence of skin injury around the port. We suggest its use instead of rigid trocar.”

Reference: Raveglia F, Cioffi U, De Simone M, et al. Advantages of wound retractor device versus rigid trocar at camera port in video-assisted thoracic surgery—a single institution experience. J Vis Surg. 2018;4:52. doi:10.21037/jovs.2018.03.15

Read the full article

Wound Retraction System for Lung Resection by Video-Assisted Mini-Thoracotomy

Excerpt: “WR [Alexis wound retractor] is comparatively a very useful tool for standard muscle-sparing posterolateral thoracotomy so as to exclude musculus serratus anterior and musculus latissimus dorsi.”

Reference: Tsunezuka Y, Oda M, Moriyama H. Wound retraction system for lung resection by video-assisted mini-thoracotomy. Eur J Cardiothorac Surg. 2006;29(4):110-111. doi:10.1016/j.ejcts.2005.10.027

Read the full article

Advantages Associated With the Use of a Wound Retractor Compared to a Rigid Trocar Inserted via the Camera Port During Video-Assisted Thoracic Surgery

Excerpt: “The [Alexis] retractor thus fits incisions that differ in both shape and size. … Retraction is atraumatic, wound protection is excellent, the exposure afforded is maximal, and the incision size is minimal. Additionally, the device does not vigorously spread the intercostal space or the intercostal muscles, thus protecting the intercostal nerves.”

Reference: Kamiyoshihara M, Igai H, Yoshikawa R, Ohsawa F, Yazawa T. Advantages associated with the use of a wound retractor compared to a rigid trocar inserted via the camera port during video-assisted thoracic surgery. J Thorac Dis. 2019;11(1):E1–E4. doi:10.21037/jtd.2018.11.15

Read the full article

Gynecology

Wound Retraction System for Gasless Laparoscopic-Assisted Myomectomy with a Subcutaneous Abdominal Wall-Lift Method

Excerpt: “Suprapubic port with 20- to 25-mm skin incision made by Alexis wound retractor to secure space that permits passage of surgeon’s forefinger … to allow the surgeon to directly palpate the myoma node and manipulate it more easily. …

“… When this device [the Alexis Wound Protector-Retractor] is used as the suprapubic working port, access to the myoma node through the wound retractor under isobaric laparoscopic condition is similar to that under open surgery.”

Reference: Takeda A, Sakai K, Mitsui T, Nakamura H. Wound retraction system for gasless laparoscopic-assisted myomectomy with a subcutaneous abdominal wall-lift method. J Minim Invasive Gynecol. 2007;14(2):240-6. doi:10.1016/j.jmig.2006.07.018

Read the full article

Laparoscopic Management of Giant Ovarian Cysts Using the Alexis Laparoscopic System: A Case Series

Excerpt: “The main incision size is substantially smaller than that of a laparotomy or a mini-laparotomy, and offers enough exposure to safely puncture the cysts in order to drain them without spillage. All masses were then extracted without having to increase the size of the incision. However, the main benefit of this technique is that it offers protection of the abdominal wound and it reduces the risk of cell spillage by using the [Alexis] wound protector-retractor.”

Reference: Dubuisson J, Heersche S, Petignat P, Undurraga M. Laparoscopic management of giant ovarian cysts using the Alexis laparoscopic system: a case series. Front Surg. 2020;7:24. doi:10.3389/fsurg.2020.00024

Read the full article

Breast

The Use of a Wound Protector as a Self Retaining Skin Retractor for Skin Sparing Mastectomy and Immediate Reconstruction

Excerpt: “We have found [Alexis wound protector-retractors] very useful in circumferential retraction required for skin sparing mastectomy without point pressure on skin which is common with metallic retractors. Reduction in contamination of the wound is an added advantage.”

Reference: Chaturvedi S, Ramsay G. The use of a wound protector as a self retaining skin retractor for skin sparing mastectomy and immediate reconstruction. Trop Med Surg. 2013;1(2). doi:10.4172/tpms.1000112

Read the full article

Personalized Surgical Strategies in Breast Cancer: Preliminary Evaluation of the Alexis Retractor for Reducing Postoperative Complications and Improving Operative Efficiency

Excerpt: “The preliminary results suggest that the Alexis® retractor may support a more personalized approach to axillary surgery in breast cancer, by reducing early postoperative complications and improving surgical ergonomics. Its atraumatic design and protective sheath may help tailor surgical management to individual patient risk profiles, minimizing tissue damage and infection risk while enhancing intraoperative visibility and efficiency.”

Reference: Scardina L, Di Guglielmo E, Accetta C, et al. Personalized surgical strategies in breast cancer: preliminary evaluation of the Alexis® retractor for reducing postoperative complications and improving operative efficiency. J Clin Med. 2025;14(21):7688. doi:10.3390/jcm14217688

Read the full article

“Moving Window” Operation for Breast-Conserving Surgery

Excerpt: “In this moving window operation for breast cancer, the wound retractor is useful not only for protecting the skin but also for providing maximum exposure with a minimum incision. Thereby, it can reduce operating time and blood loss in comparison with endoscope-assisted partial mastectomy.”

Reference: Noguchi M, Inokuchi M. “Moving window” operation for breast-conserving surgery. Breast Cancer. 2010;17:56-60. doi:10.1007/s12282-009-0104-1

Read the full article

Urology

Alexis Wound Retractor for Radical Cystectomy: A Safe and Effective Method for Retraction

Excerpt: “The Alexis retractor is a safe and elective tool for retraction and wound protection during open radical cystectomy and may potentially reduce wound-related complications, improve operative time, and lead to lower length of stay among patients. The Alexis retractor likely provides the benefit of lower surgical site infections compared to traditional retraction methods.”

Reference: Sidhu AS, Marten E, Bodoukhin N, Wayne G, Nagoda E, Bhandari A, Nieder AM. Alexis wound retractor for radical cystectomy: a safe and effective method for retraction. Adv Urol. 2018;2018:8727301. doi:10.1155/2018/8727301

Read the full article

Alexis Wound Protector/Retractor Reduces Wound Infection During Radical Cystectomy and Urinary Diversion

Excerpt: “The Alexis retractor is a useful tool for retraction and wound protection during open RC, and can be safely used in overweight and obese patients up to a BMI of 35. The Alexis retractor also may reduce wound complications and expedite operative time.”

Reference: Sidhu AS, Nagoda ET, Yanes RE, Delto JC, Bhandari A, Caso JR, Nieder AM. Alexis wound protector/retractor reduces wound infection during radical cystectomy and urinary diversion. J Urol. 2016;195(4S)(Suppl):eMP23-15.

Read the full article